ASSESSMENT OF OCCUPATIONAL RADIATION EXPOSURE IN DENTAL CLINICS USING THERMOLUMISCENCE DOSIMETERS
Authors
-
Ime Usen
Department of Radiobiology, Radiotherapy & Radiodiagnosis, College of Medicine, University of Lagos, Idi‐Araba, Lagos State, Nigeria.
-
Ayo Zacchaeus Ibitoye
Department of Radiobiology, Radiotherapy & Radiodiagnosis, College of Medicine, University of Lagos, Idi‐Araba, Lagos State, Nigeria.
-
Bidemi Akinlade
Department of Radiation Oncology, College of Medicine, University of Ibadan & University College Hospital, Ibadan, Oyo State, Nigeria.
-
Gabriel Adebayo Abe
Department of Radiobiology, Radiotherapy & Radiodiagnosis, College of Medicine, University of Lagos, Idi‐Araba, Lagos State, Nigeria.
-
Olima James Omafu
Department of Radiobiology, Radiotherapy & Radiodiagnosis, College of Medicine, University of Lagos, Idi‐Araba, Lagos State, Nigeria.
Abstract
Occupational exposure to ionizing radiation in dental clinics is gradually increasing due to the rapid increase in the use of Dental Radiography (DR) for diagnostic purposes. This study aims to estimate the scattered radiation dose received by the Operator of a dental x-ray unit during routine DR with Thermoluminescence Dosimeters (TLDs). A total of 15 dental clinics, located in the cities of Lagos and Abeokuta, were considered in this study. Annealed TLDS, each in a holder, was placed at strategic positions, where the operator stayed during the procedure. A control TLD was placed outside the radiation area of each centre to account for background. The exposed TLDs were retrieved after five consecutive imaging procedures and subsequently processed to determine the radiation dose received by the respective operators. These values were used to extrapolate their annual dose and compared with the International recommended dose limit for radiation workers. The weekly radiation dose received by the operators across all centres was less than 1 mSv, while the extrapolated annual dose ranged from 0.32 to 15 mSv, which is also below the recommended annual limit of 50 mSv. The results suggest that, notwithstanding variations in clinical and patient workflow, the risk of excessive radiation exposure to dental personnel is minimal under current operating conditions. Nevertheless, the observed inconsistency in the use of personal protective and monitoring devices in some centres underscores the necessity for strict compliance with established radiation protection practices to reduce the stochastic effects of ionizing radiation.
Keywords: Scattered Radiation, Thermoluminescence Dosimeter, Dental Radiography, Occupational Exposure, Stochastic Effect of Radiation, Radiation Protection.